Industrial software · PLC · Robotics · Commissioningmail@fiwatec.com
PLC engineering

PLC programming for machines and production systems

Development, extension, diagnostics and commissioning of PLC systems – with a focus on Siemens TIA Portal plus Beckhoff, CODESYS, Rockwell and industrial communication.

Scope

Engineering with the complete system in mind

FIWAtec combines software, commissioning and plant-level understanding. The exact scope is aligned with the installed hardware, standards and production requirements.

  • New and extended PLC sequence programming
  • Siemens TIA Portal, STEP 7, S7-1200 and S7-1500
  • WinCC and HMI/diagnostics
  • Beckhoff TwinCAT, CODESYS and Rockwell
  • PROFINET, PROFIBUS, Modbus, OPC UA, EtherNet/IP, EtherCAT
  • Troubleshooting, optimisation and production support
Software structure

Maintainable PLC code instead of temporary fixes

Clear state models, understandable interfaces, diagnostics and consistent fault response make commissioning and future modifications easier.

Integration

Connect robots, drives and field devices cleanly

PLC projects do not stop at the CPU. We consider fieldbuses, safe states, HMI, robot handshakes, distributed I/O and third-party systems.

Related

Related services

Industrial projects often require several disciplines to work together.

01

Siemens TIA Portal

S7-1200/1500, WinCC and Siemens integration.

Learn more →
Project practice

PLC programming for real production systems

PLC software must do more than look plausible in an offline test. It has to behave predictably under real machine conditions, with explicit operating modes, traceable permissions, defined fault reactions and diagnostics that support commissioning and maintenance.

Typical tasks

  • New development and extension of sequence and state control
  • Expansion of existing PLC projects while preserving proven functions
  • Integration of I/O, drives, HMI, robots and field networks
  • Troubleshooting using states, diagnostics and process signals
  • Migration, retrofit and controlled commissioning
  • Documentation of interfaces, modifications and test states

Robust implementation

Baseline & target state

Before changes, actual machine states, software version, hardware, interfaces and dependencies are captured. This creates a reliable baseline instead of assumptions.

Explicit states & interfaces

Operating modes, commands, feedback, timeouts and fault reactions are structured explicitly. This makes commissioning, diagnostics and future expansion easier.

Test & handover

Changes are not tested only for the ideal cycle. Manual mode, automatic mode, faults, communication interruptions and restart behaviour are tested and documented for the machine.

FAQ

Common questions

Which PLC platforms are covered?

The main focus is Siemens TIA Portal and STEP 7. The FIWAtec portfolio also includes Beckhoff/TwinCAT, CODESYS, Rockwell and Phoenix Contact.

Can existing software be extended?

Yes. Existing modes, interfaces and dependencies are reviewed first so proven machine behaviour is preserved.

Is commissioning part of the work?

Yes. PLC engineering is considered together with I/O tests, communication, manual mode, automatic sequence, diagnostics and production ramp-up.

How are faults isolated?

By following hardware status, communication, signal states, sequence logic and fault reactions instead of changing code at random.

Have a specific machine or task?

Discuss the technical requirements directly.

Discuss a project
E-MailProject enquiry